System design result

Posted in: , on 23. Oct. 2008 - 00:08

I design the following system:

Mass: 2500 tonne/day

belt velocity: 1.75 m/sec

width: 500 mm.

distance 1 km.

total tension: 1960 lb

power: 0.34 HP

This is the first system that I design, but Im not very sure about that power, I was expecting a something a little higher for such a distance.

Regards

Re: System Design Result

Erstellt am 22. Oct. 2008 - 11:09

I think that at the moment designing a belt conveyor is beyond your capabilities.

Rather than keep asking questions here buy the CEMA publication "BELT CONVEYORS FOR BULK MATERIALS", read it, understand it then start designing belt conveyors.

http://www.cemanet.org/publications/index.html

I would also suggest something more modest to start with than a 1km long machine.

Re: System Design Result

Erstellt am 23. Oct. 2008 - 05:09

It is a puzzle how you came to know so much from so little.

I agree with Designer's wise words.

Guessing at all information not given you might need 10 kW with a belt peak running tension = 6.5 kN.

Lawrence Nordell Conveyor Dynamics, Inc. website, email & phone contacts: www.conveyor-dynamics.com nordell@conveyor-dynamics.com phone: USA 360-671-2200 fax: USA 360-671-8450