Re: Reg Gear Box In Conveyor Sys
Gopianth..
Strange couple of questions, and I am sure we are not sure what you are realy getting at, but your answers are probably:
1) No...not in 99% of cases will it need to be reversible
2) Holdback will be required if you calculate the conveyor will run backwards when turned off with any load condition, as calculated with a low friction factor of 0.013 (You cannot put a holdback on a reversible conveyor.. you have to rely on brakes)
3) We select the drives that are able to start six times in half an hour
Regards
LSL Tekpro ■
Re: Reg Gear Box In Conveyor Sys
Ggopianth,
Bi directional as in rotating in both directions on a given installation or bi directional as in a drive suitable for multiple conveyor installations (handings) when in some cases it may be required to spin in an opposite direction to some of the other cases?
Regards,
Lyle ■
Reg gear box in conveyor sys
dear sir,
We have doubt on gear box selection Particularly on bi-direction rotation , hold back arrangement
& no of starts in belt conveyor steel guard system .
1.Is Bi-direction of gear box in conveyors necessary ?
2. will hold back arrangement required ?
And brief about no of start .
thanking u ■