Antworten
40 Mm Minus Product Wanted....
Erstellt am
6. Dec. 2011 - 05:40
if screen is at say....20 deg incline angle......put in 40mm square opening....all 4 screen sections.
at 40mm....sounds kinda like a scalping separation....plus minus 1 1/2" and down to 0" size.
DEPENDING on the specification gradation 40mm square opg or nominal 1 1/2" SQUARE should be fine. Could go a tad bigger if you desire, 42mm....which would allow for foreshortening of the opening at 20degrees....and this still would work ok.
GB ■
Best Regards,George BakerRegional Sales Manager - CanadaTELSMITH IncMequon, WI1-519-242-6664 CellE: (work) [email]gbaker@telsmith.com[/email]E: (home) [email] gggman353@gmail.com[/email]website: [url]www.telsmith.com[/url]Manufacturer of portable, modular and stationary mineral processing equipment for the aggregate and mining industries.
Correct Screen Aperture
Hello all! Itsbern a while since I ve been on here and I didn't expect to be back on with this question but here goes;
Im looming for a final product of 40mm down and have a screen are of 20*5. Feed material is an abbrssive granite and is 75-100mm down.should I just go fi
or a 42mm on all screens( this is 4 per deck) or should I mix it up a little; lime decresing the size of appetite as I move away from the feed point.
Over to you guys!!!
Thanks in advance ■