I try to use transport sugar (powder - after grinding ) very short distance (8 ft hor , 3 ft vertical) . I am interesting to use venturi pump , I like to buy from USA or UK brand ?

My question is any one have a experience in handling grind sugar ? capacity is 1 tonne/hr . My selection is correct ? where is the cheapest , quality product ?

Thanks

Uditha Kohowala

Sigma Technologies

53/46 , Eksath Mawatha

kandy Rd

kalagedihena

Sri Lanka

+94 0777 55 16 50 , +94 033 222 66 50

uditha@sigmatechnologieslk.com

uditha

Re: Grind Sugar Pumping

Erstellt am 30. Aug. 2010 - 08:47

Dear uditha,

Are you referring to a venturi-eductor system, where a compressor enters a venturi and the venturi sucks in and mixes the sugar and the mixture is blown to the destination, where a filter receiver separates the sugar from the conveying air?

Or are you referring to a venturi vacuum pump with a vacuum system?

BR

Teus

Teus

Re: Grind Sugar Pumping

Erstellt am 30. Aug. 2010 - 11:03

For the distance of 8 ft horizontal & 3 ft vertical your selection is absolutely wrong in my opinion. For 1 tph at these distances I would use a screw conveyor probably you will need a small 4” diameter screw to do the job.

Mantoo
Rod Harris
(not verified)

Re: Grind Sugar Pumping

Erstellt am 31. Aug. 2010 - 09:17

venturi should work, make sure air is dry or consider using a conveying screw for that distance, if designed properly, the screw is the best solution

Re: Grind Sugar Pumping

Erstellt am 31. Aug. 2010 - 07:07
Quote Originally Posted by Teus TuinenburgView Post
Dear uditha,

Are you referring to a venturi-eductor system, where a compressor enters a venturi and the venturi sucks in and mixes the sugar and the mixture is blown to the destination, where a filter receiver separates the sugar from the conveying air?

Or are you referring to a venturi vacuum pump with a vacuum system?

BR

Teus

Dear Mr. Teus

Yes , its venturi - eductor system, final discharging point there is small cyclon separator. one filterbag mount to top side ? bottom we collect sugar ?

concept is right ?

Thanks

uditha

uditha

Re: Grind Sugar Pumping

Erstellt am 1. Sep. 2010 - 10:06

Dear uditha,

Yes, I would say that the concept is right, although the remark of Mantoo makes also sense.

In case of chosing the pneumatic option, pay attention to the remark of Rod

For venturi's look at:

http://www.foxvalve.com/iindex2.aspx

have a nice day

Teus

Teus