Re: Grizzly Vs Eccentric Disc Screen
Mr Karthik
Grizzly will be much simpler option and less expensive.
Regards
Ziggy Gregory ■
Coal Etc.
We are facing a problem in selection of Grizzly Vs Eccentric Disc Screen in one of the project.
We got some feed back that Eccentric disc is a problematic one.
We are receiveing a coal from port. From port it is directly conveyed to Screens. Coal received size shall be 300 mm. Moisture in the range of 20 % maximum & 40% fines. Please give a suitable solution on this.
Why not simply install a coal breaker to guarantee 2 inch material and eliminate the screens if they are not installed yet?
lzaharis ■
Re: Grizzly Vs Eccentric Disc Screen
With a grizzly you have fewer parts to maintain and material does not contact the drivetrain components.
If you would be interested, our two-mass grizzly concept uses 1/3 the energy of a conventional direct drive grizzly and is custom designed for your process.
http://www.gkmining.com/proddesc.cfm/productid/93
Thank you,
Thomas Musschoot
General Kinematics Corporation
www.generalkinematics.com ■
Re: Grizzly Vs Eccentric Disc Screen
If you would be interested, our two-mass grizzly concept uses 1/3 the energy of a conventional direct drive grizzly and is custom designed for your process.
http://www.gkmining.com/proddesc.cfm/productid/93
Thank you,
Thomas Musschoot
General Kinematics Corporation
www.generalkinematics.com
Sir, can u pls tell me what is the maximum aloowable moisture % , that can be used for Grizzly screens for indian coal of -300mm input ■
Grizzley Screens
Dear Kartik,
I understand you are located in india. pl. contact us. We are the representative of M/s General Kinematics Corp. USA for India.
As regard your qurey regarding moisturem, 15% moisture can be handled without much of problem.
K.S.Nalwaya
Managing Director
KSN Tech Ventures Pvt. Ltd,
580, Sector-A, Pocket-C,
Vasant Kunj, New-Delhi-110070, India
Tel: 91 11 26894490/26121191
Fax; 91 11 26124970
Cell; 91 9811255464
E-Mail; ksnventures@gmail.com ■
Grizzly Vs Eccentric Disc Screen
Dear Sir,
We are facing a problem in selection of Grizzly Vs Eccentric Disc Screen in one of the project.
We got some feed back that Eccentric disc is a problematic one.
We are receiveing a coal from port. From port it is directly conveyed to Screens. Coal received size shall be 300 mm. Moisture in the range of 20 % maximum & 40% fines. Please give a suitable solution on this. ■