Dual Drive Problem

Posted in: , on 16. Aug. 2008 - 07:03

I have a problem with a new dual drive installation that is baffling me.

It is a 48" conveyor running a 600 FPM carrying about 2800 TPH of rock salt. Center to center of belt is 3500 ft with a 33' net lift.

I have 2 identical 250 HP motors 1780 RPM - 2300 VAC and 2 identical gear boxes Sumitomo PX8075 running 2 different pulleys on the return side of the belt approx 500' from the head pulley. The 2 drive pulleys are side by side.

This conveyor originally had a 350 HP drive on one pulley.

The primary drive pulley is 30 diameter and has a 3/4" lagging that is worn down to approx 1/2" thick.

The secondary drive pulley is 30 diameter and has new lagging on it.

The problem is that the primary drive will overload and not share the load with the secondary. Even with the belt running empty it is 40% load on the primary and 20% on the secondary.

When the belt is loaded the primary will climb to full load and the secondary may only climb to about 35% of FLA. Eventually the primary will trip on overload.

The 2 motors are fed from single 500 HP softstart. I feel it is something electrical but of course the electrical department feels it is something mechanical and are convinced it is the difference in the lagging on the pulleys.

I am starting to second guess myself and wondering if the difference in the lagging diameters could be the problem.

I have limited experience with dual drives on different pulleys.

If anyone can shed some light on this it would be most appreciative.

Gary

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Lyle Brown
(not verified)

Re: Dual Drive Problem

Erstellt am 16. Aug. 2008 - 10:51

Would have generally suggested vica versa to the situation you describe (secondary tripping) as generally the relaxation / reduction in belt speed associated with the Primary drive is seen by the Secondary. In addition the lagging wear you describe would again, appear to over load the Secondary drive.

You note soft start, hence assume no fluid coupling of any description?

Not all electric motors (even when purchased at the same time) are identical.

I assume these are SCIM and not WRIM?

Are they pulley OD's actually similar? Manufacturing tolerance may see "significant" variation in actual OD.

Assume other possible causes such as dragging brakes etc have been proven as actually (cf instrument feedback) released?

Regards,

Lyle

Re: Dual Drive Problem

Erstellt am 16. Aug. 2008 - 05:43

Thanks for the reply Lyle.

Yes both motors are SCIM.

The 2 pulleys were manufactured at the same time by the same manufacturer and are identical. The one that has the wear is the dirty side of the belt.

There is only the one 500 HP softstart and no fluid couplers. We have CT's on all 3 phases of each motor for monitioring the loads.

We have no braking system on the conveyor.

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Lyle Brown
(not verified)

Re: Dual Drive Problem

Erstellt am 16. Aug. 2008 - 10:01

So one drive is on the dirty side and one is on the clean side?

Do you have equal carry (dirty) / return (clean) cover thickness?

What sort of belt (steel cord / fabric / solid woven - unlikely etc)?

Regards,

Lyle

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 08:42

Good morning Gary.

The difference in the diameters of your drive pulleys is 1.6% (assuming you are driving on the clean side of the belt in both case. This difference of 1.6% related to the slip of the motors will cause the load sharing to deteriorate dramatically.

We have come across bad load sharing before, and the casuses have been:

- Differing lagging thicknesses

- Differing FL motor speeds

- Different exact gear ratios

- Incorrect oil fills in fluid couplings

I have never really had ay success in trying to balance loads with fluid coupling fills as you only have about 3% slip in the coupling to play with. I have always had to ensure the motor speeds, gearbox ratios lagging thicknesses etc are identical to get the required load sharing. You don't even have fliud couplings so you will have to ensure everything is identical.

Just look at your motor torque vs motor slip curves Gary.. the line gets very steep as you approach synchronous.

Cheers

LSL Tekpro

Graham Spriggs

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 03:49

Good morning Graham

I agree that with the difference in pulleys diameters would affect the loads but as Lyle has already concluded that with the primary pulley smaller than the secondary you would expect the secondary to overload on not the primary as in this case.

I also suspected that maybe the hydraulic take-up pressure was set too low when in fact it is set too high. My calculation determined that with a dual drive the T2 would actually reduce and therefore the required tension on the take-up would be less than that set for the single drive.

This makes me wonder what happens to the tension between the 2 drive pulleys. T1 coming into the primary and T2 out of the secondary - what is the tension between the primary and the secondary?

It also makes me wonder - based on the way the tensions are applied to each pulley are they accually capable of sharing the load relatively equally? Would the primary not require a higher HP than the secondary.

I have contacted our system design engineer who is now doing a thorough analysis on the system. (He was not consulted for this dual set-up.)

My total HP requirement is approx 415 HP.

My initiail solution is to install both motors on the same drive pulley. But I am concerned that they will still not share the load.

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 04:20

Originally posted by Lyle Brown

So one drive is on the dirty side and one is on the clean side?

Do you have equal carry (dirty) / return (clean) cover thickness?

What sort of belt (steel cord / fabric / solid woven - unlikely etc)?

Regards,

Lyle

Sorry Lyle I missed this!!!

The belt is a 4 ply 800 PIW Goodyear Plylon Plus fabric belt with 1/4" top cover (dirty side) and 1/8" bottom cover. All joints are hot vulcanized.

The primary drives the dirty side and the secondary drives the clean side.

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 04:21

Hi there Gary..

The following are pretty much the facts of the matter for your conveyor:

- For two drive pulleys of similar wrap, the primary drive pulley is capable of transmitting approximately 3 x that of the secondary one. This is because the tension T3 between the drive pulleys, which acts as T2 to the Primary, is higher than T2 for the Secondary. For equal wraps of theta radians, the actual ratio R of Primary to Secondary transmittable power is:

R=e^(mu x theta)

Therefore for mu=.35 and theta = PI radians (180 degrees) R= 3

- Your take up system has no bearing on the actual load sharing from two similar drive units

- If the smaller pulley is drawing more power than the larger one, I would first check that you have your Ampmeters connected to the correct drives.

- Failing that, check how many hunting teeth you have in each gearbox. In other words make sure that the exact ratios are identical. I have had this a few times before where seemingly identical boxes actually have different EXACT ratios. This occured with Flender as well as Hansen and BEW gearboxes. The last occasion was with Hansen, where their RDG 33 boxes for 2007 had different exact ratios for their RDG 33 boxes for the previous years.

- It is possible that motor on the secondary is defective, though I doubt this.

Let us know what you find Gary

Cheers

LSL Tekpro

Graham Spriggs

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 05:18

Dear Gary,

Not being an expert, but is it doable to interchange the two drives as they are identical.

And then see whether the problem stays with the drives or with the drive position.

One would expect that the load should be shared, proportional to the mechanical differences and the droop of the elctric motors.

I do not know how the stretching behavior of the belt influences all this.

Interested

Teus

Teus

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 05:50

Hi Graham

Yes the CT's are correct for each motor - we checked that as we suspected it may be backwards but it was not. The primary motor and reducer are running much hotter than the secondary.

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 06:08

Hi Gary,Graham,

Still not an expert, but, could pretensioning be an issue?

All the drive capability is used by the primary drive, leaving not enough for the secondary drive.

( the 3 times drive capabilty of the primary drive compared to the secondary drive, as Graham indicated)

Slipping should be noticable when both drive pulleys are overloaded.

BR Teus

Teus

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 09:01

As I understand the posting, you are driving the dirty side on the primary pulley and the belt dirty side has a belt cover thickness (.25 in.) 0.125 inches more than the secondary which is drive on the clean side with a belt cover of 0.125 inches.

This is the equivalent of a 0.25 in. more in relative pulley diameter.

Stated in another way, the primary pulley has a larger diameter due to the increased radius when you understand the actual driven diameter is composed of:

1. pulley radius at shell before lagging +

2. pulley lagging +

3. belt cover +

4. distance to the belt tensile member's neutral axis above items 1-3.

This last point 4 is also important in that the skim coats between fabric layers may not be symmetrical, thus the tensile member neutral axis can ship in fabric belts.

Lawrence Nordell Conveyor Dynamics, Inc. website, email & phone contacts: www.conveyor-dynamics.com nordell@conveyor-dynamics.com phone: USA 360-671-2200 fax: USA 360-671-8450
Lyle Brown
(not verified)

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 09:31

Maybe you can try "managing your lagging" (thicker on secondary, thinner on primary) to see what effect it has.

All else being equal, it appears that is where the problem is.

Regards,

Lyle

Re: Dual Drive Problem

Erstellt am 18. Aug. 2008 - 09:50

Originally posted by nordell

As I understand the posting, you are driving the dirty side on the primary pulley and the belt dirty side has a belt cover thickness (.25 in.) 0.125 inches more than the secondary which is drive on the clean side with a belt cover of 0.125 inches.

This is the equivalent of a 0.25 in. more in relative pulley diameter.

Stated in another way, the primary pulley has a larger diameter due to the increased radius when you understand the actual driven diameter is composed of:

1. pulley radius at shell before lagging +

2. pulley lagging +

3. belt cover +

4. distance to the belt tensile member's neutral axis above items 1-3.

This last point 4 is also important in that the skim coats between fabric layers may not be symmetrical, thus the tensile member neutral axis can ship in fabric belts.

Well hello Larry

Good to see you jump in here I was just about to send you an email and then saw your response.

The lagging is worn on the primary pulley and not the secondary which is what is really baffling me.

The primary drive pulley (Dirty side with 1/4" wear) would be 31" diameter and the secondary pulley (clean side with no wear) is 31.5" diameter. So this just does not make any sense to me.

Does the difference in the cover thickness change the neutral axis as it goes from one pulley to the next. The primary pulley would be on the 1/4" cover while the secondary would be on the 1/8" cover.

In other words is the neutral axis at the center of the carcass or the center of the belt as a whole?

My big question is that if everything was equal with the HP be distributed equally?????

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Re: Dual Drive Problem

Erstellt am 19. Aug. 2008 - 08:04

Hi Gary..

Would I be correct in assuming that the effective diameters of each drive pulley, (taking into account the one worn lagging, combined with the differeing thicknesses of the belt covers on each pulley with one on dirty side and one on clean side) are the same?

If so, and if you can show the exact ratios to be identical, then the secondary motor could actually be the fault.

Also, in such a case of equal effective diameters, you could swop the motor cables over to prove it isn't the electricals.

Cheers

LSL Tekpro

Graham Spriggs

Re: Dual Drive Problem

Erstellt am 19. Aug. 2008 - 11:53

Dear all,

look at the thread in this link:

https://forum.bulk-online.com/showth...=&postid=25924

Mr Nordell already mentioned there, that snub pulleys, when driven, can cause imbalances in motor load.

BR

Teus

Teus

Re: Dual Drive Problem

Erstellt am 19. Aug. 2008 - 12:48

Gary,

You are getting the insight right. Each cover contributes to the distance from pulley center to belt tensile member neutral axis.

The belt's neutral axis defines the spin radius from which the motor demand or slip speed is determined. The belt comes into the primary drive at a unknown belt speed, which is one set of the equilibrium and compatibility equations that need to be solved simultaneously, that also include:

1. belt stretch from loss of its length across the primary drive due to its drop in tension from T1 to T2

2. drive motor electric slip loss and resulting RPM

3. demand power of each drive compatible with the equilibrium that = total power draw and the electrical slip losses of the two drives that result from the differential speeds of the two drives

4. deal with reducer ratios that set compatibility between motor speeds and belt speeds.

Note: the belt will leave the primary drive slower than when it entered due to loss of length.

Generally, the larger pulley (neutral axis position) hogs the power, as it runs slower along the AC synchronous electrical slip curve of the motor, all else being equal, which in your case it is not. If pulleys are equal, then secondary will pull more power, given the secondary is fed a slower belt. There is more to this than the obvious, but I get to prattling and lose focus. Need more help write a love letter.

Lawrence Nordell Conveyor Dynamics, Inc. website, email & phone contacts: www.conveyor-dynamics.com nordell@conveyor-dynamics.com phone: USA 360-671-2200 fax: USA 360-671-8450

Re: Dual Drive Problem

Erstellt am 19. Aug. 2008 - 01:51

Dear Gary,

Another thought,

Replace the Softstart for two Volt/Hertz regulators in a master and slave setup, wherby the frequency of the secondary motor is regulated until the Amps of that motor equal the amps of the primary motor.

Also it must be possible to put all the preveous mentioned effects into a calculation scheme and investigate the respective influences on the power sharing.Should be not such a big problem for conveyor belt builders.

Success

Teus

Teus

Re: Dual Drive Problem

Erstellt am 21. Aug. 2008 - 10:56

Gary..

Do you have a system where you split the output of the soft start between the two motors so they get the same, or is it possible to programme the soft start to proportion power between the motors to different ratios?

What soft start system do you have?

Cheers

LSL Tekpro

Graham Spriggs

Re: Dual Drive Problem

Erstellt am 4. Sep. 2008 - 08:28

Just to put a closure to this thread - we ended up installing a 500 HP single drive to solve the problem.

I am convinced that the difference in the pulley lagging thickness plus the difference in the belt covers was the main problem with the motor load imbalance.

It is unfortunate as I would have rather gone with the dual drive but since the first one we ever tried failed to perform correctly I am sure another one will not be tempted.

Thanks for all the feedback everyone.

Gary

Gary Blenkhorn
President - Bulk Handlng Technology Inc.
Email: garyblenkhorn@gmail.com
Linkedin Profile: http://www.linkedin.com/in/gary-blenkhorn-6286954b

Offering Conveyor Design Services, Conveyor Transfer Design Services and SolidWorks Design Services for equipment layouts.

Re: Dual Drive Problem

Erstellt am 4. Sep. 2008 - 11:44

Gary,

To further the finality of the thread, Conveyor Dynamics, Inc. has designed and installed hundreds of multiple driven pulley systems since 1974, including inverter, hydraulic, DC-SCR and wound rotor motors with varying load share trim methods. To date, not one has given any problem and has been predictable.

I note 1974 is when I designed the world's first inverter drive for a belt conveyor system for the La Caridad mine in Mexico. Four inverters started 20 drives with up to 2400 hp, with steel cord and fabric belts, many different power ratios, et al.

Our power range is to 10,000 kW per conveyor, head and tail remote by up to 16 km, load cell (tension), velocity and torque controls

Good engineering makes good projects, lack of good engineering is Las Vegas.

Lawrence Nordell Conveyor Dynamics, Inc. website, email & phone contacts: www.conveyor-dynamics.com nordell@conveyor-dynamics.com phone: USA 360-671-2200 fax: USA 360-671-8450

Re: Dual Drive Problem

Erstellt am 5. Sep. 2008 - 08:32

Oh dear Gary...

Your thread reminds me of a who-dunnit book, that has the last page missing!

I have always been wary of a dual drive operating off a single soft start, and hoped to learn from your tribulations. Especially as I am considereing it for one of my applications at present.

So I was wondering if anyone out there has actually had any success using a single soft start on a conveyor fitted with a dual pulley drive?

Cheers

LSL Tekpro

Graham Spriggs

Re: Dual Drive Problem

Erstellt am 5. Sep. 2008 - 10:58

Dear Graham,

They have done you one better. They connected two driven pulleys through a common gearbox. Not done today, but you might recall the period when this applied to underground coal mines. They did so with clean side dirty side drives as well.

If they can make that work, then one inverter powering two pulleys is of the same mold.

However, it was not a good idea as they found heavy wear and lack of load sharing as you might expect. It just tears and wears the belt and lagging as you probably know, or I hope you know, and they cannot get full motor capacity delivered to the two motors.

For giggles, why do you ask?

Lawrence Nordell Conveyor Dynamics, Inc. website, email & phone contacts: www.conveyor-dynamics.com nordell@conveyor-dynamics.com phone: USA 360-671-2200 fax: USA 360-671-8450

Re: Dual Drive Problem

Erstellt am 5. Sep. 2008 - 01:56

Hi Larry..

We had this guy from a VSD company to give us a speel on what they can and what they cannot do with electrically controlled starts.

At that time he said soft starts are for single drives only.

Since then, a company from down under told us they could do a dual drive no problem from a single soft starter.

The sad experiences of poor old Gary have cast doubt that the blokes from down under are fully up to speed.

The best way I though to really find out is to ask if anyone has proved the concept in practice.

If it works it would be great, but does it??

Giggle on young man...it's Friday and the fridge is full of cold beer and biltong.

Cheers

LSL Tekpro

Graham Spriggs
rekhawar
(not verified)

Re: Dual Drive Problem

Erstellt am 6. Sep. 2008 - 09:29

Dear all,

I do not have experience with Dual Drive conveyors. Two such conveyors I worked with, in both the place second drive was not installed, as it was the phase II capacity.

From the discussion and my experience, I have following points to mention:

1. The difference in the thickness of lagging is being thought over, since both the drive pulleys are near to each other. But, the problem of unequal load sharing occurs when drive pulleys are distant apart also.

2. I feel that problem is with the Electrical soft start for pulleys. If we provide fluid couplings on high speed side of both the drives. the difference in rotation speed, torque will be absorbed by slip in fluid couplings. Load sharing has to be done dynamically,as per situation. Provision of fluid coulings in place of VVVFD, may be the solution.

If I am wrong, experts may correct me.

Regards

P. Rekhawar

David Beckley
(not verified)

Load Sharing

Erstellt am 7. Sep. 2008 - 05:54

Hi Gary,

You have done a number of things on this conveyor that may be low cost options on paper but that can and will cause problems. I would not recommend this design concept for the following reasons :-

1. I would never use a fabric reinforced belt with a dual drive system that is driven directly by SC motors; this belt has a low elastic modulus and the change in length around the drive pulley will cause significant load sharing problems.

With a typical SC motor the slip at full load is approximately 1% (15 rpm in 1500), so it follows that if you have a speed variations of 0.1% you will get a 10% variation in the load!!! You could be getting as much as 1% speed variation with a fabric belt hence your problem.

2. I would not drive on both the carry and return sides of the belt for a variety of reasons including the variation in the pitch diameter as already highlighted by others.

3. I would not use a soft starter. These devices are good for starting fans but not so good for belt conveyors where a high torque is required throughout the start. VVVF control would be more expensive but will work and would solve your problems.

Whoops, I somehow missed the bit about going to a single drive pulley. I must stop reading this forum late at night!!!!

Regards,

David Beckley.