Clinker Storage Terminal

Author
(not verified)
Posted in: , on 1. Mar. 2006 - 20:15

Dear Sir,

Egyptian Cement Company - ECC - located at 93Km Kattamia Rd. Suez, Egypt, calls for a selective tender to make the Engineering design of a clinker storage terminal to be located at Dameitta Port.

ECC objective is to construct a clinker storage facility with a life capacity of 30'000 tons clinker and to be operating within 6 months after approving your offer and signing the contract. Your role, Scope of Work, is to generate an offer comprising all engineering works necessary, design of civil, steel, mechanical, electrical and instrumentations designs, and imported deliveries to construct a clinker storage/terminal bearing in mind all technical specifications and constraints listed below. These are as follows:

Clinker Storage Capacity demanded 30'000 tons.

Output from storage demanded 800-1000 tons per hour transfer conveying system to Dameitta port berth.

Input to storage, filling rate, demanded 400-500 tons per hour unloading / feeding system.

Distance from storage to Dameitta port berth is about 120 meters.

No Restrictions had been made for the proposed layout.

Bulk Trucks or so called silo trucks, ECC property, to feed the flat storage. Each Silo truck carries between 35 to 50 tons, average 45 tons per truck.

One of your design criteria is that your design meets EEAA standards; i.e.: design complies with international safety standards.

Flat Clinker storage should comprise appropriate dedusting system and ventilation system to hinder any dust dissipations into surrounding air.

Labor power and maintenance works should be as minimum as possible during operation works. Your design of equipment should be almost maintenance free.

A system of unloading from silo trucks is needed to evacuate them, to reach 400-500-t/hr.

You are kindly requested to submit your initial proposal for the design and system arrangement, and once we agreed upon, you will be requested to formulate a lump sum tender, currency in Dollars or Euros, comprising the complete engineering of the clinker storage terminal. We expect your initial proposal not later than Calendar WEEK #10.

However, your complete and final offer should comprise the following items:

1. Breakdown of Imported equipment technical specifications and prices.

2. Alternative designs, if any.

3. Proposed local equipment and parts, i.e.: steel structures that may be found in local market.

4. supervision on erection, commissioning and testing of all works included in this facility prices.

5. A complete plan for detailed engineering works, local and imported manufacturing, delivery to site location and erection works prior to commissioning.

6. Any experience from your side in synonym facilities for eligibility purposes.

Thank you in advance.

Kind Regards

Mohamed Saad

PMT

Ext.# 275

Cellular #: +2 012 33 84 804

Mohamed.Saad@ecc-eg.ne

Re: Clinker Storage Terminal

Erstellt am 2. Mar. 2006 - 04:44

DEAR Mohamed Saad, SLAM ALYKUM

I have seen your post,your requirement is to go for flat storage,fin, but please think of following--

1.Flat silos are good where-

land cost is not high.

bearing capacity of soil is very poor.

where the project life is not long.

where electricity and labour is cheap.

pollution norms are not very strict.

feeding and evacation rates are not very high.

For your information the size of flat shed for 30,000 capacity shall be around--200mx40mx8m(h) with comparing to dome dia approx-45 -50 m

you will have to spend heavily on the following if you will go for flat silo--

pollution control equipment like dust filters

electricity

labour

dosing equipment

reclaiming equipment

maintenance

In the beginening the flat storage may be cheaper but if you will add all above costs,it may not be good idea to go for flat silo.

regards,

ANIL

LIBRAN ENGINERING AND SERVICES

IF YOUR GODSELF NEEDS WE CAN DEVELOP A VERY GOOD LAY OUT WITH ALL OTHER FACILITY,LIST OF EQUIPMENT FOR BOTH THE OPTIONS-DOME AND FLAT.WE HAVE JUST FINISHED SIMILAR TYPE OF JOB FOR ONE OF OUR CLIENTS IN KUWAIT WHERE WE HAVE GONE FOR--60,000 T CEMENT STORAGE AND 45,OOO TPD DESPATCH PLANT FOR CEMENT.

WE ARE ALSO DESIGNING INDIA'S BIGGEST COAL TERMINAL WITH A DUTCH CO.

ANIL

LIBRAN ENINEERING AND SERVICES

0091-0-9811055650

Re: Clinker Storage Terminal

Erstellt am 8. Mar. 2006 - 03:19

DEAR Mohamed Saad, SLAM ALYKUM,

Thanks for accepting our recommendations,please also note that if in that area rainfall is very less, their is no need to cover clinker .

REGARDS, ANIL