I am re-designing the pulverized fuel pipelines for one of our coal fired power stations. A coal mill serves 4 pipes and each pipe is connected to one burner. The variations of the solids flow to the 4 burners are quite large.

We want to balance the flow with orifice plates, but I cannot find a formula for 2-phase flow. I am also looking for a formula to calculate the pressure drop in 2-phase flow across a sudden reduction in the pipe.

Your help will be appreciated.

Thanks,

Jan

Re: Orifice Pressure Drop

Erstellt am 15. Sep. 2003 - 09:28

Dear Jan,

If the massflow after your splitter is unbalanced may have different reasons:

1.) unsufficient flow conditions in front of splitter

2.) wrong type of splitter (especially for coal feeding)

3.) unbalanced ductwork after splitter

If you can eliminate 1.) and/or 2.) at least 3.) remains. You have to adjust massflow into the 4 lines. Orifices in general cause instabilities, better is a additional pressure loss at the end of the line so that this pressure loss is the main loss in the system.

This can be done by adding nozzles.